site stats

Dataphysics oca40

Webintervals with a sessile drop goniometer (Dataphysics OCA40, Germany) on allthreetypes of PETsurfaces.Figure 2shows the setup of the inkjet–contact angle goniometer system. … Webhigh pressure chamber with optical sapphire glass. high pressure unit for generation and control of bulk liquid/gas pressure and drop liquid/gas pressure (manual or automatic) …

Facile Fabrication of Superhydrophobic Surface with Excellent ...

WebThe processes of frost formation on the i-PP films were observed using CA System OCA40 (Dataphysics Co., Germany) with a maximum magnification of ×2000 as microscopic image system (Fig. S1). Humidity controller (Beijing YaDu Technical Company for Cleaning Air, Ltd.) is used to control the relative humidity. WebJul 21, 2024 · The droplet contact angles were measured using a Dataphysics OCA40 Micro (Filderstadt, Germany). The volume of the DI water droplets used was 3 microliters. Surface wettabilities were tested at a constant temperature of 25 °C and relative humidity of 58%. All the data were determined by averaging five individual measurements. greeley brunch https://elitefitnessbemidji.com

静电纺光致变色PMMA纤维的制备与表征_参考网

WebOct 4, 2024 · The microstructure of the f-SiO 2 particles and surface morphology of the hydrophobic surfaces were observed by scanning electron microscope (SEM, Nova NanoSEM 430, FEI). The water contact angle (WCA) of the samples was measured by utilizing an optical contact angle measuring equipment (Dataphysics OCA40 Micro … WebWettability of the surface of Ti6Al4V specimens was examined by an optical water contact angle (WCA) measuring device (Dataphysics OCA40 Micro, Germany) using 1 µL of deionized water at 25 °C and 45% humidity. ... (Dataphysics, Germany). For statistical analysis of differences in water contact angles, a one-way ANOVA following Dunnett’s ... WebJan 12, 2024 · The OCA 25 is the all-purpose measuring device for contact angle measurements and the drop shape analysis.For large samples the OCA 25L is equipped with long... flower for lisa genshin impact

DataPhysics Instruments

Category:Contact Angle Meter Dataphysics OCA 40 Micro Microscope Full …

Tags:Dataphysics oca40

Dataphysics oca40

DataPhysics Instruments

WebApr 5, 2010 · 谭连江,刘水平,万锕俊(1.上海交通大学化学化工学院 上海 200240;2.东华大学纤维材料改性国家重点实验室 上海 201620)静电 WebDec 3, 2024 · The surface topography of the titanium samples was identified by scanning electron microscopy (SEM, Hitachi SU70, Japan). The water contact angles were measured with an optional contact angle measuring device (Dataphysics OCA40 Micro, Germany). The roughness was scanned by a 3D surface topography analyzer (Rtec UP Series, …

Dataphysics oca40

Did you know?

WebFeb 15, 2024 · The preparation method of D-SCG is shown in Fig. 1.SCG was initially delignified with 5 wt% NaOH aqueous solution at 90 °C for 1 h. The processed sample was extracted with 10 wt% H 2 O 2 solution at 90 °C for 34 h. Then, the sample was washed with distilled water 2–3 times until the cleaning solution was neutral. WebManufacturer: DATAPHYSICS Model: OCA 40 Category: MASK & WAFER INSPECTION. CAE has broad access to semiconductor related equipment direct from fabs, often …

Web本发明属于基因工程和材料基因组学领域,公开了一种利用材料基因组学构建具有目标材料性能的丝蛋白的方法,以及通过该方法制备的具有目标材料性能的丝蛋白以及丝蛋白材料。本发明采用了材料基因组学方法对丝蛋白的材料性能进行了筛选、分析和研究,与传统方法相比,节约了研究成本 ... WebDec 25, 2013 · Norbert Heil at DataPhysics, Germany and Mikael Sundin at SP are thanked for technical support of the OCA40 instrument. The investigation is part of the NextJet …

http://www.asi-team.com/asi%20team/dataphysics/DataPhysics%20data/OCA40%20micro.pdf WebMar 10, 2024 · Webinar Video: Vibration Data Acquisition to MATLAB with the Data Physics QUATTRO API. Last Updated on March 10, 2024 by dpnew Vibration Data Acquisition to …

http://www.asi-team.com/asi%20team/dataphysics/DataPhysics%20data/OCA10-20.pdf

WebApr 6, 2024 · The experiments were carried out with a dataphysics OCA40 micro-static contact angle system. Three different locations for each sample were selected to ensure the accuracy of the measurements. Results and discussion XRD and microstructure analysis. flower for germanyWebFilderstadt, November 22, 2024. Since August 1997, DataPhysics Instruments has been developing, manufacturing, and distributing laboratory measuring devices for the … flower for january birthdayWebMar 23, 2024 · Additionally, to ensure superhydrophobicity, a contact angle instrument (Dataphysics, OCA40) was used to measure the advancing and receding contact angles of CS and CLS. The measurement method from was adopted, and measurements were performed three times on each substrate. The contact angle hysteresis was calculated … flower forksWebMay 30, 2012 · 水接触角测定用德国DataPhysics公司的OCA-40型接触角测定仪,测定水在不同涂膜上的接触角。微注射器液滴量有机–无机杂化复合涂层形成机理有机–无机杂化复合涂层的制备机理示意图如图1所示。 greeley building inspectionWeb(Waltham, US); a micro surface contact meter Dataphysics OCA40 was from Dataphysics (Stuttgart, Germany); and a scanning electron microscope S‐3700N was from Hitachi (Tokyo, Japan). 2.2. flower forget me not pictureWebS2 a glass substrate and kept under a nitrogen atmosphere for 48 h to remove the residual solvents. Fabrication of solar cells: Patterned indium tin oxide (ITO) glass substrates were pre-cleaned ... greeley buffalo wild wingsWebJan 3, 2024 · The wettability of separator was characterized by contact Angle (Dataphysics OCA40 Micro, Germany). The morphology and structure characterizations were carried out on field emission scanning electron microscope (FESEM; Sigma 500, ZEISS, Germany). greeley building department permit search